| 104516290 | over 4 years ago | problem fixed. |
| 36047654 | over 4 years ago | longer isolator = more possible voltage. 1m or 3 ft = 100 kV. 3m = 300-400 kV. More parallel isolators are mandatory for the physical weight of the line. |
| 36047654 | over 4 years ago | It is posible to guess the maximum possible operational voltage by the length of the isolators. It could be operatetd on a lower voltage and also on a slightly higher voltage, than written on signs, because there is some security buffer in everything. Like a 110 kV-line can be operated at 130 kv. You can't read the exact number. But if you have a small amount of possible values (138 kv, 275 kv, or 345 kV), you could guess the correct number. |
| 36047654 | over 4 years ago | Hmm, I don't know which detail you mean? USA has a frequency of 60 Hz everywhere. Worldwide nearly all electric circuits have 3 phases (cables=3,6,9,12). Only exception would be HVDC or 1-phase systems in german-speaking Europe. What else? voltage is the same on every connected line, till the next transformer change this. If arial image uality is high enough, you can see the type of wires. |
| 104810247 | over 4 years ago | Vor etwa einem Monat habe ich am Anfang und Ende der Leitung (Mast 3 und 67) die Beschriftung ermittelt. dabei waren diese durchgehend konsistent. Da du jetzt einen 'neuen' Mast gefunden hast, musste an einer anderen Stelle ein Mast zu viel sein und der Fehler irgendwo dazwischen liegen. Und tatsächlich war die Nr. 50 zu viel. Das habe ich korrigiert. |
| 78067079 | about 5 years ago | Ich habe im UW Blankenhagen ein bisschen rumgekritzelt. Hoffe es stört dich nicht. ;-) |
| 78067079 | about 5 years ago | Der Zugang ist nicht vom Verkehrsmittel (motor_car,bicylce,foot) abhängig. Der Eigentümer/Betreiber entscheidet. Der Zaun ist generell zu. Das OSM-Wiki sagt: "No access for the general public." |
| 76844455 | almost 6 years ago | Ich hatte Ende September eine Treffen in Karlsruhe mit anderen Leuten und mich intensiv unterhalten. Tatsächlich ist die Frequenz nicht Teil der (physikalischen) Infrastruktur, sondern eine veränderbare Betriebsweise des elektrischen Systems. Die Information der Frequenz ist weiterhin auf der Relation. |
| 78597749 | almost 6 years ago | Hochspannungsleitung wurde für den Abzweig nach Herzberg auf historisch geändert. Dort gab es eine Notiz, dass der Abschnitt abgebaut sei. |
| 67397342 | almost 7 years ago | Yes, that's correct. There is a power line, but no energy on it. Only steel cables between two poles to hold physical forces of attached lines. |
| 63466395 | about 7 years ago | Thanks for the hint. I didn't know this feature. In this special case I meant to connect it ot the farmland border. |
| 63488995 | about 7 years ago | Thanks for correcting my "wrong move". |
| 52599689 | about 8 years ago | Da habe ich natürlich vertippt und werde es gleich korrigieren. |
| 42580874 | about 9 years ago | That was an error of mine. I corrected this with changeset/42719449 |
| 42580874 | about 9 years ago | sorry, just saw the error. These nodes are power=transformer and this tag was missing. |
| 42580874 | about 9 years ago | Number of uses for tags:
|
| 26197233 | over 9 years ago | Die Strommasten standen vor zwei Monaten immer noch. Ohne Leitung, aber sie sind tatsächlich da. Die Masten sollten also in OSM auch stehen bleiben! |
| 35737655 | about 10 years ago | Inzwischen sind die beiden Brücken in jeweils zwei ways umgewandelt und ein Loch (keine Verbindung) dazwischen. Das sollte meiner Ansicht nach die realistischste Variante sein. Auch auf lange Zeit. |
| 13026699 | over 10 years ago | untagged way fixed |
| 30249713 | over 10 years ago | fixed. |