1. minor cleanup

    Closed
    #158867900 0 6 5 0
  2. these substations are 110/35kV including the traction station. Lines around here identified as 35kV are not consistent with the tower builds they are attached to. Find a 110kV sub to work out from, such as Темпы to work out from.

    Closed
    #158867665 0 2 0 0
  3. correction of 330 & 220kV circuits from river crossing to powerstation. two 330kV share towers in northern section. 200kV circuit is on 500kV towers crossing cooling canal W-E 1wire (330kV), 2wire (330kV), 1wire (220kV)

    Closed
    #158867007 14 18 13 0
  4. 220kV crosses river 3rd tower south. two 330kV circuits cross river on single tower (middle). 220kV feeds 35kV substation (transformers there) as it crosses over it. 35kv circuits east of sub questionable... 220kV extends here. streetview verified

    Closed
    #158865854 9 13 10 0
  5. realignment. East of river, two 330kV circuits on 1 tower although one has single wire, while other has double wire. Dual 220kV splits near 750kV at tower east of road (seen on street view) 220kV crosses river on 3rd tower south 1 of 2 to correct

    Closed
    #158864853 18 8 5 0
  6. There are no fucking 220kV/35kV single phase transformers in Russia!!! Therefore, there are no transformers connecting 500kV & 35kV switchyards. Stop reverting my edits if you don't know what the fuck it is that I am correcting!

    Closed
    #158789272 2 8 15 3
  7. https://wiki.openstreetmap.org/wiki/Key:design#Towers_or_pylons

    Closed
    #158755405 0 3 2 1
  8. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158705439 0 3 8 2
  9. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158705209 0 9 18 1
  10. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158704980 0 23 26 1
  11. Corrections to substation. Historical shows 500kV yard built in 2010-13, but never commissioned as 500kV

    Closed
    #158704384 19 8 21 1
  12. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158701544 0 14 14 1
  13. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158700989 2 10 15 1
  14. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158700638 1 6 11 1
  15. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158699925 0 8 18 1
  16. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158698878 0 4 12 1
  17. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158698547 0 5 14 1
  18. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158698165 0 6 8 1
  19. stop splitting out phases of the same circuit based on the number of towers at a change of direction.

    Closed
    #158697908 0 11 49 1
  20. .

    Closed
    #158680700 0 1 0 0